12V 24V 48V 96V 30-70A MPPT Solar Charge Controller
MPPT Technical Parameter
GD-40A/50A/60A | 30A | 40A | 50A | 60A | 70A | |
Charging Mode | Advanced Maximum Power Point Tracking MPPT | |||||
Charging Method | Absorption, Float, Equalization, for optimal battery charging | |||||
System type | 12V-48V series,48V-96V series Automatically identify battery voltage, manually set voltage battery |
|||||
System identify Voltage Range(battery voltage) 12V-48V system |
12V system | DC9V-DC15V(Automatically identify) | ||||
24V system | DC18V-DC30V(Automatically identify) | |||||
36V system | Manually Set(Not supported Automatically identify) | |||||
48V system | DC36V-DC60V(Automatically identify) | |||||
System identify Voltage Range(battery voltage) 48V-96V system |
48V system | |||||
60V system | Manually Set(Not supported Automatically identify) | |||||
72V system | ||||||
96V system | DC72V-DC120V(Automatically identify) | |||||
Soft start time | 12V/24V/48V/96V | ≤10s | ||||
Dynamic response recovery time | 12V/24V/48V/96V | ≤500us | ||||
Static power | 12V/24V/48V/96V | ≤2W | ||||
Overall efficiency | 12V/24V/48V/96V | ≥95% | ||||
PV module utilization (tracking accuracy) |
12V/24V/48V/96V | ≤99.97% | ||||
INPUT | ||||||
Solar panel input voltage range (MPPT operating voltage range) |
12V system | DC18V-DC150V | ||||
24V system | DC36V-DC150V | |||||
36V system | DC54V-150V | |||||
48V system | DC65V-DC150V | |||||
72V system | DC100V-DC180V | |||||
96V system | DC120V-DC180V | |||||
Input low voltage protection voltage | 12V system | DC16V | ||||
24V system | DC30V | |||||
36V system | DC45 | |||||
48V system | DC60V | |||||
72V system | DC84V | |||||
96V system | DC115V | |||||
Input low voltage recovery voltage | 12V system | DC18V | ||||
24V system | DC36V | |||||
36V system | DC54V | |||||
Mode:GD-40A/50A/60A | 30A | 40A | 50A | 60A | 70A | |
Input low voltage recovery voltage | 48V system | DC65V | ||||
72V system | DC100V | |||||
96V system | DC120V | |||||
Input overvoltage protection point | 12V-48V SERIES | DC175V | ||||
48V-96V SERIES | DC235V | |||||
Input Overvoltage Recovery Point | 12V-48V SERIES | DC170V | ||||
48V-96V SERIES | DC175V | |||||
Mode:GD-40A/50A/60A | 30A | 40A | 50A | 60A | 70A | |
Maximum solar panel input power | 12V system | 450W | 570W | 700W | 900W | 1100W |
24V system | 950W | 1130W | 1400W | 1700W | 2200W | |
48V system | 1900W | 2270W | 2800W | 3400W | 4400W | |
96V system | 3600W | 4540W | 5600W | 6800W | 7800W | |
DC output | 12V-48V SERIES | Same voltage as the battery, 30A maximum allowable output current | ||||
48V-96V SERIES | No DC output | |||||
Optional battery type (factory default is lead-acid maintenance-free battery) |
12V-48V SERIES | Lead-acid maintenance-free batteries, gel batteries, liquid batteries, lithium batteries | ||||
48V-96V SERIES | ||||||
Float charging voltage (lead-acid battery) lithium battery must be determined in strict accordance with the requirements of the battery manufacturer |
12V system | 13.8V(Customizable float voltage) | ||||
24V system | 27.6V(Customizable float voltage) | |||||
36V system | 41.4V(Customizable float voltage) | |||||
48V system | 55.2V(Customizable float voltage) | |||||
60V system | 69V(Customizable float voltage) | |||||
72V system | 82.8V(Customizable float voltage) | |||||
96V system | 110.4V(Customizable float voltage) | |||||
Equalizing voltage (lead-acid battery) lithium battery without equalizing charge |
12V system | 14.5V(Customizable float voltage) | ||||
24V system | 29V(Customizable float voltage) | |||||
36V system | 43.5V(Customizable float voltage) | |||||
48V system | 58V(Customizable float voltage) | |||||
60V system | 72.5V(Customizable float voltage) | |||||
72V system | 87V(Customizable float voltage) | |||||
96V system | 116V(Customizable float voltage) | |||||
Rated charging current | 12V/24V/48V/96V | 30A | 40A | 50A | 60A | 70A |
Maximum limited charge current | 32A | 42A | 52A | 62A | 72A | |
Temperature Coefficient | ±0.02%/℃ | |||||
Automatic temperature compensation (lead-acid battery) |
14.2V-(Maximum temperature-25℃)*0.3 | |||||
型号:YH-30A/40A/50A/60A/70A | 30A | 40A | 50A | 60A | 70A | |
Output voltage regulation accuracy | 12V/24V/48V/96V | ≤±1% | ||||
Display | LCD/LED | |||||
PC Host computer (communication port) |
RS485(Optional) | |||||
Protection | ||||||
Input low voltage protection voltage | Have | |||||
Input high voltage protection | Have | |||||
Overcharge protection | Have | |||||
PV input reverse polarity protection | Have | |||||
Battery reverse polarity protection | Have | |||||
Output short circuit protection | Have | |||||
Over temperature protection | 85℃ | |||||
temperature rise protection | Over 80℃ reducing power output | |||||
Others | ||||||
Noise | ≤50dB | |||||
Cooling method | Forced air cooling, the fan speed is adjusted by the temperature, when the internal temperature is low, the fan runs slowly or stops; When the controller stops working, the fan stops running; |
|||||
Odor | Does not produce odors and unhealthy odors | |||||
Environmental requirements | Complies with 2002/95/EC; free of cadmium, hydride and fluoride | |||||
Attributes | ||||||
Item Size | 252mmX182mmmX80mm | |||||
Packing Size | 310mmX250mmmX135mm | |||||
Weight(net) | 2.6KG | 2.7KG | 3.3KG | 3.4KG | 3.45KG | |
Package (Gross weight add 0.3-0.4Kg) | Cartoon | |||||
Type of mechanical protection | IP21 | |||||
Environmental requirements | ||||||
Humidity | 0~90%RH ( No condensation) | |||||
Altitude | 0~3000m | |||||
Ambient temperature | Below 20℃, above 40℃ | |||||
Atmospheric pressure | 70~106kPa |
Write your message here and send it to us