High Efficiency 120kw 150kw Hybrid Solar Inverter for Commercial Industrial
Datasheet | HPS 30 | HPS 50 | HPS 100 | HPS 120 | HPS 150 |
AC(Grid-connected) | |||||
Apparent power | 33kVA | 55kVA | 110kVA | 132kVA | 165kVA |
Rated power | 30kW | 50kW | 100kW | 120kW | 150kW |
Rated voltage | 400V | 400V | 400V | 400V | 400V |
Rated current | 43A | 72A | 144A | 173A | 217A |
Voltage range | 360V - 440V | 360V - 440V | 360V - 440V | 360V - 440V | 360V - 440V |
Rated frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Frequency range | 45~55/55~65Hz | 45~55/55~65Hz | 45~55/55~65Hz | 45~55/55~65Hz | 45~55/55~65Hz |
THDi | <3% | <3% | <3% | <3% | <3% |
PF | 0.8lagging~0.8leading | 0.8lagging~0.8leading | 0.8lagging~0.8leading | 0.8lagging~0.8leading | 0.8lagging~0.8leading |
AC connection | 3/N/PE | 3/N/PE | 3/N/PE | 3/N/PE | 3/N/PE |
AC(Off-grid) | |||||
Apparent power | 33kVA | 55kVA | 110kVA | 132kVA | 165kVA |
Rated power | 30kW | 50kW | 100kW | 120kW | 150kW |
Rated voltage | 400V | 400V | 400V | 400V | 400V |
Rated current | 43A | 72A | 144A | 173A | 217A |
THDU | ≤2%linear | ≤2%linear | ≤2%linear | ≤2%linear | ≤2%linear |
Rated frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
Overload capability | 110%- 10 mins120%- 1 min | 110%- 10 mins120%- 1 min | 110%- 10 mins120%- 1 min | 110%- 10 mins120%- 1 min | 110%- 10 mins120%- 1 min |
DC(battery and PV) | |||||
Max PV Open-circuit voltage | 1000 VDC | 1000 VDC | 1000 VDC | 1000 VDC | 1000 VDC |
Recommended PV power | 30kWp | 50kWp | 100kWp | 120kWp | 150kWp |
PV MPPT voltage range | 480VDC-800VDC | 480VDC-800VDC | 480VDC-800VDC | 480VDC-800VDC | 480VDC-800VDC |
Recommended nominalbattery voltage | 420V | 420V | 420V | 420V | 420V |
Battery voltage range | 352-600V* | 352-600V* | 352-600V* | 352-600V* | 352-600V* |
Max. charge/discharge power | 30kW | 50kW | 100kW | 120kW | 150kW |
Max. charge/discharge current | 85A | 142A | 285A | 340A | 425A |
General Information | |||||
Protection degreeNoise emission Environment temperature CoolingRelative humidityMaximum altitude
Dimension (W/H/D) Weight Build-in transformer Transfer between on/off grid Standby consumption |
IP20<65dB(A)@1m-25 °C… +55 °CForced-air
0 ~95% non-condensing 6000m (derate over 3000m) 950/1860/750mm 440kg yes Automatic≤10ms <30W |
IP20<65dB(A)@1m-25 °C… +55 °CForced-air
0 ~95% non-condensing 6000m (derate over 3000m) 950/1860/750mm 620kg yes Automatic≤10ms <30W |
IP20<65dB(A)@1m-25 °C… +55 °CForced-air
0 ~95% non-condensing 6000m (derate over 3000m) 1200/1900/800mm 900kg yes Automatic≤10ms <30W |
IP20<65dB(A)@1m-25 °C… +55 °CForced-air
0 ~95% non-condensing 6000m (derate over 3000m) 1200/1900/800mm 1024kg yes Automatic≤10ms <30W |
IP20<65dB(A)@1m-25 °C… +55 °CForced-air
0 ~95% non-condensing 6000m (derate over 3000m) 1400/1900/800mm 1250kg yes Automatic≤10ms <30W |
Communication | |||||
DisplayCommunication interface | Touch screenRS485/CAN | Touch screenRS485/CAN | Touch screenRS485/CAN | Touch screenRS485/CAN | Touch screenRS485/CAN |